Kidde KN-COSM-IB Hardwire Combination Carbon Monoxide and Smoke Alarm with Battery Backup and Voice Warning, Interconnectable
Kidde KN-COSM-IB Hardwire Combination Carbon Monoxide and Smoke Alarm with Battery Backup and Voice Warning, Interconnectable
Product Details
- Product Dimensions: 2 x 6 x 6 inches
- Shipping Weight: 1.3 pounds (View shipping rates and policies)
- Shipping: Currently, item can be shipped only within the U.S. and to APO/FPO addresses. For APO/FPO shipments, please check with the manufacturer regarding warranty and support issues.
- ASIN: B00032NDSG
- Item model number: 21006377
- Batteries: 1 9V batteries required. (included)
By : Kidde
List Price :
Price : $32.75
You Save : $29.24 (47%)
Item Description
Amazon.com Item Description
The KN-COSM-IB combines a Carbon Monoxide and Ionization Smoke Alarm, providing two vital safety devices in a single unit. This alarm consists of a voice warning technique that helps remove confusion, as it tells you if its detected fire or carbon monoxide, or even if it demands a new battery. This alarm has 9 volt battery backup, which protects you and your loved ones - even throughout a power outage when numerous incidences occur. The alarm also makes it possible for you to effortlessly silence nuisance alarms using its handy Intelligent Hush feature. This talking combo alarm is powered by your home’s electricity and can interconnect with other smoke alarms in your house. Professionals advocate interconnected alarms, simply because when 1 sounds, they all sound, delivering an early warning against fire by drastically escalating your capability to hear an alarm anywhere in your household, regardless of exactly where the fire begins.
Kidde KN-COSM-IB Hardwire Mixture Smoke and CO Alarmwith 9V Battery Backup
- Employs each smoke andcarbon monoxide sensors.
- Inter-connectable to deliver improved protection
- Attributes a hush button to silence the alarm for non-emergency situations like a smoky dinner.
Protects from two distinctive hazards, smoke and carbon monoxide. .
Provides the advised protection of an interconnected method. When a single alarm goes off, they all do. .
Provides the suggested protection of an interconnected technique. When 1 alarm goes off, they all do. .
Mixture Smoke/CO Alarm for Improved SafetyThe Kidde Combination Carbon Monoxide Smoke Alarm contains a voice warning program that eliminates confusion and clearly warns you and your household of a smoke or carbon monoxide danger, or if your battery is in want of replacement or your alarm is in hush mode.
Alarm Warnings Fire: The red LED will flash and be accompanied by three extended alarm beeps followed by a verbal warning message “Fire! Fire!” The alarm will repeat pattern until smoke is eliminated.
Carbon Monoxide: Four short alarm beeps followed by a verbal warning “Warning! Carbon Monoxide!” This continues till the unit is reset or CO is eliminated.
Low Battery: A single chirp followed by warning “Low Battery” The red LED light will flash. This pattern will continue each minute for the to begin with hour. After the initially hour the red LED light will flash when every single minute accompanied by the chirp sound. The low battery warning will only sound as soon as each and every fifteen minutes.
Voice Hush Indication: “Hush Activated” and “Hush Cancelled” voice announcement
Peak Level Memory: If the alarm had detected a CO level of 100ppm or higher when the Test/Reset button is pressed, the unit will announce “Carbon Monoxide Previously Detected” to warn of the CO incident.
Inter-connectable for Improved SafetyFire and consumer authorities advocate interconnected alarms for added protection. According to the National Fire Protection Association (NFPA), most Americans feel they are far more at risk of getting a victim of a tornado than of a house fire. Essentially the opposite is correct. Fires are far more normal than any other disaster that strikes a loved ones at house, and can develop into deadly in minutes.
You have on average much less than three minutes from the time you hear a smoke alarm to escape a fire. The sooner you hear an alarm, the sooner you can get out safely. Smoke alarms that link together so that when 1 goes off, they all go off, are named interconnected alarms. These alarms provide additional warnings in significantly more areas, giving your loved ones additional time to escape a residence fire. Houses built immediately after 1993 are required by constructing codes to have interconnected alarms that are wired into their electrical method.
Trademarked Hush Feature for ConvenienceBy pressing the Hush button, you can readily and safely silence nuisance alarms caused by non-emergency circumstances, such as overcooked dinners.
This feature desensitizes the alarm for around ten minutes. If the smoke is not too dense, the alarm will silence promptly, the unit will verbally announce “Hush Mode Activated,” and the green LED will flash every single 2 seconds for approximately ten minutes.
Trustworthy 9-Volt Battery Backup, Indicator LED, Test Feature, Low Battery and End-of-Life Warning
The alarm’s 9-volt battery backup gives continuous protection, even throughout power outages. For the reason that this alarm only aids protect you if it is working, this unit capabilities a red LED that flashes each and every 30 to 40 seconds to indicate that it is operating correctly. For additional peace of thoughts, the alarm also contains a test/reset button that enables you to periodically test its circuitry and horn.
If any form of battery failure is detected the red LED light will flash and the unit will “chirp” a single time, followed by the warning message “Low Battery.” This cycle will take place once every minute, and will continue for at least seven days.
Seven (7) years just after initial power up, this unit will “chirp”every 30 seconds. This is an “operational finish of life” feature which will indicate that it is time to replace the alarm. UL 2034, the independent standard applicable to CO alarms, calls for CO alarms to have an end of life warning. This requirement went into impact in March 2007, which means any CO alarm manufactured soon after April 2007 with a UL listing ought to have this feature. Most states that call for CO alarms in residential dwellings mandate that the alarm meet the UL 2034 typical.
The unit measures just five.75 inches in diameter and 1.7 inches deep, and it features a neutral, white finish. It includes tamper resist attributes to deter vandalism or theft. This mixture smoke/CO alarm is UL listed, so you can be confident of its excellent, and it is backed by a 5-year restricted warranty.
About Kidde: A UTC Fire Security Brand Renowned for global leadership in fire detection and suppression, Kidde offers solutions ranging from portable fire extinguishers to advanced industrial controls such as flame detection and explosion suppression systems. Kidde is a UTC Fire Security brand, with a history that’s wealthy with innovations, from the patent of the Chubb Detector Lock in 1818 to the development of the world's very first wireless networked smoke detectors in 2004.
What is in the BoxCombination smoke and carbon monoxide alarm with mounting bracket and mounting hardware, fast-connect wiring harness, one 9 volt battery, a five-year restricted warranty and a bilingual (English/Spanish) user's manual.
From the Manufacturer
The leading lead to of accidental poisoning deaths in North America, Carbon Monoxide is odorless, tasteless and invisible. It is a silent killer. Kidde CO alarms include the most accurate sensing technology accessible, the patented Nighthawk electrochemical sensor. This unit combines a Carbon Monoxide and Ionization Smoke Alarm, providing two very important safety devices in a single unit. This alarm consists of a voice warning method that announces "Fire, Carbon Monoxide, Low Battery or Wise Hush Activation." The voice alarm eliminates any confusion and clearly warns you and your household of a smoke or carbon monoxide danger, or if your battery is in want of replacement. This unit is hardwired and will function with various interconnected systems. This combination alarm has battery backup, protecting you and your family even throughout a power outage when various incidences happen. Install at least one particular CO alarm on every single floor and in sleeping regions. Make certain CO and Smoke alarms are at least 15 feet away from cooking or heating appliances to prevent false alarms. Replace CO alarms just about every five to 7 years to benefit from the most up-to-date technologies upgrades. Ionization sensing alarms might detect invisible fire particles related with quickly flaming fires sooner than Photoelectric alarms. Studies show each sorts will properly detect either sort of fire. For optimal protection, install both smoke alarm technologies in your household.
Kidde KN-COSM-IB Hardwire Combination Carbon Monoxide and Smoke Alarm with Battery Backup and Voice Warning, Interconnectable
Technical Details
- Talking alarm announces the hazard type detected, helping to speed up reaction time
- Combined carbon monoxide and smoke alarm, a single unit can be installed where previously two were needed
- Battery safeguard ensures the unit cannot be accidentally mounted without batteries
- Test-reset button tests alarm circuitry and triggers the voice announcement
- Meets safety standards set by Underwriters Laboratories (UL)
Customer Reviews
Purchased five of these for use in our personal home with the intent to buy more for rentals if they performed well. Really liked the idea of having a voice warning that tells what the problem is and was thrilled at how easy the installation was...for about 48 hours.
About two days after initially installation, started getting a "beep" but no voice indication of low battery/other. We always keep spare batteries in stock so decided to replace the batteries with fresh ones and problem seemed to go away. Temporarily.
A few days later the alert goes off again which of course, signals ALL of them to go off as they are interconnected. This time it indicates a dead battery. Odd since we replaced them but figured our batteries may have been older than we realized. Went to the store and bought all new batteries - replaced in all five units.
A few nights later - about 2 in the morning - we get a full fledged alert with the 'WARNING -FIRE!" screeching through the house. After peeling ourselves off the ceiling, we took down the one main culprit and figured that one may be a lemon. Since we have five in the house, we still felt it may be an isolated problem...EXCEPT
The Next night we get yet another screeching alert...."WARNING - Carbon Monoxide". It should be worth mentioning to note that we had NO fireplace burning and do NOT cook or heat with anything other than electricity. In fact, nothing was running whatsoever.
At this point, we're exhausted from several nights of interrupted sleep and all of these are going back. The good news is the interconnected portion works. The bad news is the constant false alarms will leave you likely to take them down in order to get a full nights sleep.
In all our years of smoke alarms these have given more false alerts in just a couple weeks than the past 20 years combined. SKIP~!
Replaced a 10 year old BRK Smoke Detector...This Kidde is Great! Hookup took less than 5 minutes, just replaced old pigtail connector, with the included Kidde connectors. The Kidde base feels more sturdy and the sure-lock twist design guaranteed a perfect fit. The Kids love the "voice" warnings (test mode) for Fire ; Carbon Monoxide...I also love the visible 120v power indication (green light). Did I mention that Amazon.com has the best price on this unit...yeah, pick one up!
Kidde KN-COSM-IB Hardwire Combination Carbon Monoxide and Smoke Alarm with Battery Backup and Voice Warning, Interconnectable
Rating: 4.5
Post a Comment